products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
CEMS System
Created with Pixso.

NMTHC FID VOCs Gas Analyzer CEMS System with 0-100mg/m3 OEM Range, ≤2% Repeatability, and ≤120s Response Time

NMTHC FID VOCs Gas Analyzer CEMS System with 0-100mg/m3 OEM Range, ≤2% Repeatability, and ≤120s Response Time

Brand Name: JUGE
Model Number: AG-VOCS-09
MOQ: 1 Unit
Price: USD10000-20000
Payment Terms: T/T,Online order
Supply Ability: 100 Unit/Week
Detail Information
Place of Origin:
Nanjing, China
Certification:
IOS9001, CE
Product Name:
CEMS For Non-Methane Total Hydrocarbon
Nmthc Range:
0-100mgc/m3 OEM
Repeatability:
≤2%
Response Time:
≤120S
Linearity Error:
≤±2%F.S.
24H Zero Drift And Range Drift:
≤±2%F.S.
1week Zero Drift And Range Drift:
≤±2%F.S.
Packaging Details:
Neutral carton
Highlight:

NMTHC CEMS System

,

Hydrocarbon CEMS System

,

FID cems gas analyzer

Product Description
NMTHC FID Vocs Gas Analyzer CEMS Monitoring System For Non Methane Total Hydrocarbon
Overview

Used for real-time online monitoring of volatile organic compounds (VOCs) emissions from industries such as petrochemical, painting, injection molding, coatings, textile, electronics, and automobile manufacturing.

The system uses a high-temperature-resistant diaphragm pump to extract exhaust gas, which is then pre-treated for dust removal before being sent to the gas chromatograph for analysis. By combining catalytic oxidation and FID principles, it can quickly and effectively obtain monitoring data.

Key Features
  • Uses catalytic method with minimal background interference, fast analysis cycle, and quick real-time data response
  • High detection sensitivity and low resolution
  • High catalytic efficiency and long lifespan
  • Fully automated system design with fault alarms for easy maintenance and repair
Technical Parameters
Items Parameter
NMTHC Monitoring Unit
NMTHC (0-100)Mgc/m³, OEM
O2 (0-25)%
Repeatability ≤2%
24-Hour Zero Drift And Range Drift ≤±2%F.S.
One Week Zero Drift And Range Drift ≤±3%F.S.
Linearity Error ≤±2%F.S.
Analysis Cycle ≤120s
Flue Gas Parameter
Temperature Range: (0-300)ºC, OEM
Accuracy: ≤±3ºC
Pressure Range: (-2.5-2.5)Kpa
Accuracy: ≤0.5%
Velocity Of Flow Range: (0-40)m/s, (0-2)Kpa, Optional
Accuracy: ≤±5%
Humidity Range: (0~40)Vol%
Accuracy: ±2%
Data Acquisition And Processing Unit
Data Transmission Module 8 Way Analog Input
1 Way Rs485
IPC 6 Way Rs232
Windows7
Software Vocs Monitoring Software V3.0
Power Supply AC 220V, 50Hz, ≤7Kw
System Components
Online Gas Chromatography FID Non-Methane Total Hydrocarbon Continuous Emission Monitoring System
Online Gas Chromatography FID Non-Methane Total Hydrocarbon Continuous Emission Monitoring System
CEMS Online SO2 NO NO2 Continuous Emission Monitoring System Flue Gas Analyzer
CEMS Online SO2 NO NO2 Continuous Emission Monitoring System Flue Gas Analyzer