| Brand Name: | JUGE |
| Model Number: | AG-TDGA-7000 |
| MOQ: | 1 Unit |
| Price: | USD4000-10000 |
| Payment Terms: | T/T,Online order |
| Supply Ability: | 100 Unit/Week |
The AG-TDGA-7000 positive pressure explosion-proof laser gas analysis system perfectly combines Tunable Diode Laser Absorption Spectroscopy (TDLAS) and Multi Reflection Long Path Technology to improve detection sensitivity and provide the best solution for online monitoring of hydrogen sulfide.
| Gas | Measuring Range | Resolution | Repeatability | Linearity | Response Time | Drift |
|---|---|---|---|---|---|---|
| NH3 | 0-100mg/m³ | 0.01mg/m³ | ≤1%FS | ≤1%FS | ≤15S | ≤ ±1%FS |
| HCL | 0-100/300mg/m³ | 0.01mg/m³ | ≤1%FS | ≤1%FS | ≤15S | ≤ ±1%FS |
| HF | 0-100/300mg/m³ | 0.01mg/m³ | ≤1%FS | ≤1%FS | ≤15S | ≤ ±1%FS |
| Preheat | 30min |
| Power Supply | AC220V/3KW |
| Digital output | RS232/485 |
| Analog output | 4-20mA maximum load 900 Ω |
| Measuring Optical path | 8m |
| Sample gas temperature | ≤ 300 ℃ |
| Sample gas pressure | Atmospheric pressure ± 5kPa |
| Sampling flow | ≤3L/min |
| Ambient temperature | -20~50℃ |
| Sampling method | Extraction Type |
| Size | 330(W)×1150(L)×1560(H)mm |
| Weight | 120kg |