Extraction Type Laser Gas Analyzer CEMS with Fast Response ≤15S Maintenance Free Design and Eliminates Dust Interference

Extraction Type Laser Gas Analyzer CEMS with Fast Response ≤15S Maintenance Free Design and Eliminates Dust Interference

Brand Name: JUGE
Model Number: AG200SQ
MOQ: 1 Unit
Price: USD10000-20000
Payment Terms: T/T,Online order
Supply Ability: 100 Unit/Week
Detail Information
Place of Origin:
Nanjing, China
Certification:
ISO9001 , CE
Product Name:
Extraction Type Laser Gas Analyzer
SO2 Range:
0-100mg/m3 OEM
NO Range:
≤300S
NO2 Range:
0-100mg/m3 OEM
O2 Range:
0-25%
Repeatability:
≤2%
Response Time:
≤120S
Linearity Error:
≤±2%F.S.
CO2 Range:
0-20%
CO Range:
0-500mg/m3 OEM
Nmthc Range:
0-100mgc/m3 OEM
24H Zero Drift And Range Drift:
≤±2%F.S.
1week Zero Drift And Range Drift:
≤±2%F.S.
Range:
0-100 Ppm/mg/m3
Display Error:
≤±5%
Drift:
≤±2.5%F.S
Gas Parameter:
NH3, HCL, HF
Packaging Details:
Neutral carton
Highlight:

Fast Response Laser Gas Analyzer

,

Maintenance Free CEMS

,

Dust Interference Continuous Emission Monitoring System

Product Description
Extraction Type Laser Gas Analyzer
Laser Gas Analyzer HCl CO CEMS Waste Incineration AEMS Monitoring Equipment Continuous Emission Monitoring System
Overview
The laser gas analyzer utilizes tunable semiconductor laser absorption spectroscopy (TDLAS) technology. It scans and analyzes gas absorption spectra at specific wavelengths, enabling precise gas concentration measurement through advanced technologies including digital lock-in amplifiers and long optical path gas chambers. As one of the most advanced gas measurement methods available, this instrument features high sensitivity, rapid response, immunity to background gas interference, and non-contact measurement, providing reliable monitoring of NH3, HF, and HCl concentration changes.
Key Features
  • Fast response time
  • Eliminates dust, tar, and background gas interference
  • Maintenance-free design with low operating costs
  • Minimal measurement value fluctuation with high reliability
  • Optional explosion-proof design available
Technical Specifications
Performance Parameters
Gas Measuring Range Resolution Repeatability Linearity Response Time Drift
NH3 0-100mg/m³ 0.01mg/m³ ≤1%FS ≤1%FS ≤15S ≤ ±1%FS
HCL 0-100/300mg/m³ 0.01mg/m³ ≤1%FS ≤1%FS ≤15S ≤ ±1%FS
HF 0-100/300mg/m³ 0.01mg/m³ ≤1%FS ≤1%FS ≤15S ≤ ±1%FS
Functional Parameters
Preheat 30min
Power Supply AC220V/3KW
Digital Output RS232/485
Analog Output 4-20mA maximum load 900 Ω
Environmental Parameters
Measuring Optical Path 8m Sample Gas Temperature ≤ 300 ℃
Sample Gas Pressure Atmospheric pressure ± 5kPa Sampling Flow ≤3L/min
Ambient Temperature -20~50℃ Sampling Method Extraction Type
Size 330(W)*1150(L)*1560(H)mm Weight 120kg