| Brand Name: | JUGE |
| Model Number: | AG-RA101 |
| MOQ: | 1 Unit |
| Price: | USD5000-10000 |
| Payment Terms: | T/T,Online order |
| Supply Ability: | 100 Unit/Week |
The environmental radiation online monitoring station can instantly obtain the ambient radiation level in its area, monitor its trends and anomalies, meeting the needs of real-time monitoring and rapid response. The environmental monitoring station system integrates multiple systems such as a central station, monitoring substations, emergency monitoring vehicles, and environmental monitoring vehicles, providing low power consumption, green environmental protection, modular design, and an efficient basis for emission compliance decisions through pre‑management and post‑treatment.
The fixed monitoring station is set at a fixed location for continuous automatic sampling and measurement of environmental quality. Inside and outside the station building, there are various detection devices such as samplers, meteorological detectors, and environmental dose rate meters, simultaneously obtaining environmental radiation dose and meteorological information. The data is stored and displayed on a local processing computer, and is also uploaded in real‑time to a central computer via a wired or wireless dedicated network for storage and display.
Sampling frequency is adjustable from as low as 1 second to several days continuously.
Data with a 5‑second interval can be stored for more than 3 months.
Battery life exceeds 24 hours.
Supports real‑time data communication and historical data retrieval.
Linearity within the measurement range is better than 1%.
>>Main technical parameters
| Parameter Category | Parameter Name | Value |
| Mechanical Characteristics | Vibration | Structurally robust, impact resistance |
| Flutter | 1.0J three times, change ≤15% | |
| Alarm | Alarm Type | Failure / out-of-range / overload alarm |
| Alarm Threshold | User configurable | |
| Temperature & Humidity Adaptability | Operating Temperature | -25°C ~ +60°C |
| Humidity | ≤95% | |
| Electromagnetic Compatibility (EMC) | Electrostatic Discharge (ESD) | Contact 4kV, air 8kV; reading change ≤ ±15% |
| RF Electromagnetic Field | 80MHz~1GHz, 1.4GHz~2.5GHz, field strength 10V/m; reading change ≤ ±15% | |
| Burst (EFT) | ±2kV, 1 min; change ≤ ±15% | |
| Surge | ±2kV, 1 min; change ≤ ±15% | |
| RF Conducted Immunity | 150kHz~80MHz, 10V; change ≤ ±15% | |
| Oscillatory Wave | Oscillation frequency 1MHz ±10%; change ≤ ±15% | |
| 50Hz Magnetic Field | 50Hz, 30A/m, two orientations; change ≤ +15% | |
| Voltage Dip | Criterion B (device shall operate continuously after test) |