| Brand Name: | JUGE |
| Model Number: | AG600-VOC |
| MOQ: | 1 Unit |
| Price: | USD2000-5000 |
| Payment Terms: | T/T,Online order |
| Supply Ability: | 100 Unit/Week |
Fast response, capable of promptly providing feedback on the operation status of treatment equipment and the activity of activated carbon, effectively reducing enterprises' treatment costs.
Equipped with an imported British Alphasense PID sensor, enabling stable and efficient detection of VOCs.
Excellent front-end pretreatment system that dries and filters the detected gas, ensuring more accurate gas detection, more stable operation, and effectively extending sensor life.
All gas pathways are made of corrosion-resistant materials to avoid adverse effects caused by corrosive gases.
All interfaces use components with excellent airtightness to ensure the validity of gas detection.
Features historical data storage, allowing alarm data and records to be viewed at any time.
Adopts the standard HJ212 protocol, seamlessly connecting to regional environmental protection platforms.
Outdoor solar power supply with low-power design – no wiring required.
>>Main technical parameters
| Parameter | Description |
| Detected Gases | VOC, VOCs, TVOC, non-methane total hydrocarbons, benzene series, etc. (total emission concentration) |
| Detection Principle | PID photoionization (imported sensor) |
| Detection Method | Fixed pump-suction online continuous detection |
| Measurement Range | 0-10 ppm, 0-500 ppm (μmol/mol) (Optional; ranges not listed are customizable) |
| Resolution | 0.01, 0.1, 1 ppm |
| Indication Error | ≤10% F.S (actual concentration; higher accuracy depends on sensor performance) |
| Installation Method | Wall-mounted, floor-standing, pole-mounted |
| Repeatability | ≤±0.5% |
| Zero Drift | ≤±5% F.S/year |
| Span Drift | ≤±5% F.S/year |
| Response Time | ≤15 seconds (T90) |
| Recovery Time | ≤20 seconds |
| Alarm Method | Audible and visual alarm; 1 or 2 dry contact outputs; alarm value adjustable |
| Protection Grade | Detector: IP66; Whole system: IP54 |
| Operating Temperature | -20°C ~ +200°C (special requirements can be customized) |
| Operating Humidity | ≤95% RH, non-condensing (if humidity >90% RH, a filter can be equipped) |
| Humidity Compensation | Relative humidity 10%~95% RH; instrument has built-in full-range temperature and humidity compensation |
| Power Supply | Monocrystalline solar panel: 10W collection efficiency; 60AH large-capacity battery. Can operate for about 3 consecutive days under cloudy/rainy conditions (assuming fully charged) |
| Power Consumption | 40W |
| Operating Pressure | ≤200 kPa |
| Data Storage | Built-in storage capacity; optional memory card |